| |
Automatic High Speed Injectable Powder Filling with Rubber Stoppering Machine |
|
| |
TECHNICAL DETAILS |
|
| |
Production Rate |
|
| |
|
120 Fills/Min. for Single Dose |
|
60 Fills/Min. for Double Dose |
|
40 Fills/Min. for Tripple Dose |
|
30 Fills/Min. for Four Dose |
|
|
| |
|
|
| |
Power Specification |
|
| |
|
1.5 H.P, 440 Volts, 3 Phase, 4 Wire System, 50 Hz. |
|
|
| |
|
|
| |
Fill Capacity |
|
| |
|
50 mg. to 1.5 gm. in single dose with the help of extra change parts |
|
|
| |
|
|
| |
Optional Accessories |
|
| |
|
Pure Air Filter |
|
Vacuum Pump |
|
Oil Free Air Compressor |
|
Online Pre-Media filling Arrangement |
|
Pre & Post Gassing Arrangement |
|
Programmable Logic Control (PLC) System with MMI |
|
Aluminium Profile with Polycarbonate Cabinet covering full Machine |
|
|
| |
|
|
| |
Accuracy |
|
| |
| |
± 1% depending upon consistency and uniformity of bulk density of Injectable Powder under controlled level of humidity (below 28% Rh) |
|
|
| |
|
|
| |
Overall Dimension |
|
| |
|
2800mm (L) x 842mm (W) x 1700mm (H) |
|
Net Weight : 655 kg. Gross Weight : 1010 Kgs. |
|
|
| |
|
|
| |
Input Specification |
|
| |
|
Container Dia. : 25mm to 38mm |
| |
Container Height : 36mm to 75mm max. |
| |
Rubber Stopper : 20mm Butyl |
|
|
| |
|
|
| |
Utility |
|
| |
| |
Compressed Air : Max. 2 Kg /Cm2 Oil Free |
| |
Vaccum : 25" Hg. @ 300 LPM Displacement |
| |
Relational Humidity : Below 28% |
|
|
| |
|
|
| |
Salient Features |
|
| |
|
“No Vial - No Filling” system eliminates wastage of costly Powder. |
|
Multiple Dosing System |
|
High Volumetric Filling Accuracy of ± 1% of uniform density Injectable Powder can be ensured by setting the depth of piston in the Port of the Powder Wheel. |
|
Built-In Rubber Stoppering Unit saves lot of space in the Sterile Area & reduces the length of the Laminar Flow. |
|
Individual drives for Scrambler & Un-scrambler to match the speed of filling and sealing |
|
All Motors are provided with appropriate Contactors and Relays for the protection against any overload or Jamming. |
|
Safety clutch system to avoid Vial breakage |
|
Variable Frequency Drive for speed control |
|
All contact parts ae easily removable for Autoclaving / Sterilization |
|
|
| |
|
|
| |
|
|
| |
HOME | COMPANY | PRODUCTS | INQUIRY | OUR REACH | CONTACT US |
| |
© Copyright 2007, Ambica Pharma Machines Pvt. Ltd. |
|